Brochure Request
- Clear Vision REF series X-ray flat panel detectors incorporate the proven technology of amorphous silicon. The amorphous silicon photodiode array and TFT underneath convert invisible X-ray photons into visible photons, and then into electric charges.The electron signals are measured and amplified in the data line, and then converted to digital signals by the Analog/Digital converter. Finally, the digital signals are transmitted to a PC for processing to from an image. High DQE, high spatial resolution, extraordinary dynamic range and ultra-low noise are hallmarks of our Clear Vision REF series. Each Clear Vision REF detector is submitted for FDA and CE approval.


| Optimized UI design for Touch screen |
| Multi-task Patient |
| Imaging and Annotation Tools (Window level, Zoom, Pan, Crop, Invert, Rotation, Angle, Label, Text) |
| Powerful User Features (Image stitching, Image import / export, Image comparison, Multi view, Image expansion, Full screen, Auto collimation, Reject/Accept) |
| Smart Window Level |
| DICOM3.0 Compatibility |
| Post Image processing mode for each body part |
| Changeable Skin color (Green Tea, Strawberry, Mint, Chocolate, Banana, Vanilla) |


X-ray Detector
-
750Cw
-
1500C
-
1500Cw
-
1500L
-
1500P
-
1800Cw
-
1800L
-
1800Le
-
1500Cwe
-
1800Cwe


| Sensor | |
| Scintillator | Direct Deposit CsI:TI |
| Active Area | 307.2x 244.32 mm |
| Scintillator | 2560 x 2048 |
| Pixel Pitch | 120 μm |
| Image Quality | |
| Limiting Resolution | 4.16 lp/mm |
| MTF | 70%... … (@ 1 lp/mm) |
| 40% … … (@2 lp/mm) | |
| 40% … … (@2 lp/mm) | |
| 15% … … (@4 lp/mm) | |
| DQE | (RQA5, 14μGy) |
| ~ 70% … … (@ 0 lp/mm) | |
| ~ 40%… … (@ 3lp/mm) | |
| Sensitivity | ~ 0.62 ct/nGy |
| Response Non-linearity | <± 0.5 % |
| Maximum Linear Dose | >95μGy |
| Dark Noise | ~ 10 nGy |
| Dynamic Range | ~ 82 dB |
| A/D Conversion | 16 bits |
| Communication | |
| Communication interface | Gigabit Ethernet 2.4G/5GHz, 300 Mbps |
| Image Acquisition Time | 2-3 Sec |
| Exposure Control | F²AED |
| Manual Sync | |
| Enviornmental | |
| Operating | |
| Temperature Range | 5℃-35℃ |
| Humidity Range (Non-condensing) |
30% - 75% RH |
| Storage | |
| Temperature Range | -20℃-55℃ |
| Humidity Range (Non-condensing) |
10% - 90% RH |
| Water/Dust Proof | IP 64 |
| Mechanical | |
| Dimensions | 333 x 268 x 15 mm |
| Weight | ~ 2.3 kg |
| Housing Material | Carbon Fiber (Front) |
| Aluminum Alloy(Back) | |
| Power | |
| Maximum Power (standby / operating) |
< 8W / 17W |
| Power Supply | 100-250V AC |
| Frequency | 50 / 60 Hz |
| Battery | 3260 mAh, 14.8V |


| Sensor | |
| Scintillator | Direct Deposit CsI:TI |
| Active Area | 433.7x 354.8mm |
| Pixel Array | 2816 x 2304 |
| Pixel Pitch | 154 μm |
| Image Quality | |
| Limiting Resolution | 3.25 lp/mm |
| MTF | 70%... … (@ 1 lp/mm) |
| 40% … … (@2 lp/mm) | |
| 22% … … (@3 lp/mm) | |
| DQE | (RQA5,27μGy) |
| ~ 65% … … (@ 0 lp/mm) | |
| ~ 20%… … (@ 3lp/mm) | |
| Sensitivity | ~ 0.50 ct/nGy |
| Response Non-linearity | <± 0.5 % |
| Maximum Linear Dose | >95μGy |
| Dark Noise | ~ 8 nGy |
| Dynamic Range | ~ 82 dB |
| A/D Conversion | 16 bits |
| Communication | |
| Communication interface | Gigabit Ethernet |
| Exposure control | F²AED |
| Manual Sync | |
| Enviornmental | |
| Operating | |
| Temperature Range | 5℃-35℃ |
| Humidity Range (Non-condensing) |
30% - 75% RH |
| Storage | |
| Temperature Range | |
| Humidity Range (Non-condensing) |
10% - 90% RH |
| Mechanical | |
| Dimensions | 460 x 384x 15 mm |
| Weight | 3.3 kg |
| Housing Material | Carbon Fiber (Front) |
| High Strength Aluminum Alloy(Back) | |
| Power | |
| Maximum Power (standby / operating) |
< 8W / 22 W |
| Power Supply | 100-250V AC |
| Frequency | 50 / 60 Hz |
| Regulatory | |
| FDA | K153058 |
| CE | HD601077350001 |
| UL | E464810 |


| Sensor | |
| Scintillator | Direct Deposit CsI:TI |
| Active Area | 433.7 x 354.8mm |
| Pixel Array | 2816 x 2304 |
| Pixel Pitch | 154 μm |
| Image Quality | |
| Limiting Resolution | 3.25 lp/mm |
| MTF | 70%... … (@ 1 lp/mm) |
| 40% … … (@2 lp/mm) | |
| 22% … … (@3 lp/mm) | |
| DQE | (RQA5,27μGy) |
| ~ 65% … … (@ 0 lp/mm) | |
| ~ 20%… … (@ 3lp/mm) | |
| Sensitivity | ~ 0.62 ct/nGy |
| Response Non-linearity | <± 0.5 % |
| Maximum Linear Dose | >95 μGy |
| Dark Noise | ~ 8 nGy |
| Dynamic Range | ~ 82 dB |
| A/D Conversion | 16 bits |
| Communication | |
| Communication interface | Gigabit Ethernet 2.4G/5GHz, 300 Mbps |
| Image Acquisition Time | 2-3 sec(wired) |
| 4-5 sec(wireless) | |
| Exposure control | F²AED |
| Manual Sync | |
| Enviornmental | |
| Operating | |
| Temperature Range | 5℃-35℃ |
| Humidity Range (Non-condensing) |
30% - 75% RH |
| Storage | |
| Temperature Range | -20℃-55℃ |
| Humidity Range (Non-condensing) |
10% - 90% RH |
| Mechanical | |
| Dimensions | 460 x 384x 15 mm |
| Weight | 3.7 kg |
| Housing Material | Carbon Fiber (Front) |
| High Strength Aluminum Alloy(Back) | |
| Power | |
| Maximum Power (standby / operating) |
< 8W / 20W |
| Power Supply | 100-250V AC |
| Frequency | 50 / 60 Hz |
| Battery | 3260 mAh, 14.8V |
| Regulatory | |
| FDA | K153058 |
| CE | HD60107735000 |
| UL | E464810 |
| Health Canada | 96952 |


| Sensor | |
| Scintillator | Direct Deposit CsI:TI |
| Active Area | 433.7x 354.8mm |
| Pixel Array | 2816 x 2304 |
| Pixel Pitch | 154 μm |
| Image Quality | |
| Limiting Resolution | 3.25 lp/mm |
| MTF | 70%... … (@ 1 lp/mm) |
| 40% … … (@2 lp/mm) | |
| 22% … … (@3 lp/mm) | |
| DQE | (RQA5,27μGy) |
| ~ 65% … … (@ 0 lp/mm) | |
| ~ 20%… … (@ 3lp/mm) | |
| Sensitivity | ~ 0.50 ct/nGy |
| Response Non-linearity | <± 0.5 % |
| Maximum Linear Dose | >95 μGy |
| Dynamic Range | ~ 82 dB |
| A/D Conversion | 16 bits |
| Communication | |
| Communication interface | Gigabit Ethernet 2.4G/5GHz, 300 Mbps |
| Image Acquisition Time | 2-3 Sec |
| Exposure control | F²AED |
| Manual Sync | |
| External Sync | |
| Enviornmental | |
| Operating | |
| Temperature Range | 5℃-35℃ |
| Humidity Range (Non-condensing) |
30% - 75% RH |
| Storage | |
| Temperature Range | -20℃-55℃ |
| Humidity Range (Non-condensing) |
10% - 90% RH |
| Mechanical | |
| Dimensions | 460 x 384x 15 mm |
| Weight | 3.4 kg |
| Housing Material | Carbon Fiber (Front) |
| Aluminum Alloy(Back) | |
| Power | |
| Maximum Power (standby / operating) |
< 8W / 20W |
| Power Supply | 100-250V AC |
| Frequency | 50 / 60 Hz |
| Regulatory | |
| FDA | K153058 |
| CE | HD601077350001 |
| UL | E464810 |


| Sensor | |
| Scintillator | Direct Deposit CsI:TI |
| Active Area | 433.7x 354.8mm |
| Pixel Array | 2816 x 2304 |
| Pixel Pitch | 154 μm |
| Image Quality | |
| Limiting Resolution | 3.25 lp/mm |
| MTF | 70%... … (@ 1 lp/mm) |
| 40% … … (@2 lp/mm) | |
| 22% … … (@3 lp/mm) | |
| DQE | (RQA5,27μGy) |
| ~ 65% … … (@ 0 lp/mm) | |
| ~ 20%… … (@ 3lp/mm) | |
| Sensitivity | ~ 0.62 ct/nGy |
| Response Non-linearity | <± 0.5 % |
| Maximum Linear Dose | >95 μGy |
| Dark Noise | ~ 8 nGy |
| Dynamic Range | ~ 82 dB |
| A/D Conversion | 16 bits |
| Communication | |
| Communication interface | Gigabit Ethernet 2.4G/5GHz, 300 Mbps |
| Image Acquisition Time | 2-3 sec(wired) |
| Exposure control | F²AED |
| Manual Sync | |
| Enviornmental | |
| Operating | |
| Temperature Range | 5℃-35℃ |
| Humidity Range (Non-condensing) |
30% - 75% RH |
| Storage | |
| Temperature Range | -20℃-55℃ |
| Humidity Range (Non-condensing) |
10% - 90% RH |
| Mechanical | |
| Dimensions | 477.4 x 353.6 x 18.4 mm |
| Weight | 4 kg |
| Housing Material | Carbon Fiber (Front) |
| High Strength Aluminum Alloy(Back) | |
| Power | |
| Maximum Power (standby / operating) |
< 8W / 20W |
| Power Supply | 100-250V AC |
| Frequency | 50 / 60 Hz |
| Battery | 3260 mAh, 14.8V |
| Regulatory | |
| CE | HD601077350001 |


| Sensor | |
| Scintillator | Direct Deposit CsI:TI |
| Active Area | 433.5 x 433.5mm |
| Pixel Array | 2816 x 2304 |
| Pixel Pitch | 154 μm |
| Image Quality | |
| Limiting Resolution | 3.25 lp/mm |
| MTF | 70%... … (@ 1 lp/mm) |
| 40% … … (@2 lp/mm) | |
| 22% … … (@3 lp/mm) | |
| DQE | (RQA5) |
| ~ 65% … … (@ 0 lp/mm) | |
| ~ 33%… … (@ 3lp/mm) | |
| Sensitivity | ~ 0.62 ct/nGy |
| Response Non-linearity | <± 0.5 % |
| Maximum Linear Dose | >95 μGy |
| Dark Noise | ~ 8 nGy |
| Dynamic Range | ~ 82 dB |
| A/D Conversion | 16 bits |
| Communication | |
| Communication interface | Gigabit Ethernet 2.4G/5GHz, 300 Mbps |
| Image Acquisition Time | 2-3 sec(wired) |
| 4-5 sec(wireless) | |
| Exposure control | F²AED |
| Manual Sync | |
| Enviornmental | |
| Operating | |
| Temperature Range | 5℃-35℃ |
| Humidity Range (Non-condensing) |
30% - 75% RH |
| Storage | |
| Temperature Range | -20℃-55℃ |
| Humidity Range (Non-condensing) |
10% - 90% RH |
| Mechanical | |
| Dimensions | 460 x 460 x 15 mm |
| Weight | 4 kg |
| Housing Material | Carbon Fiber (Front) |
| High Strength Aluminum Alloy(Back) | |
| Power | |
| Maximum Power (standby / operating) |
< 8W / 20W |
| Power Supply | 100-250V AC |
| Frequency | 50 Hz |
| Battery | 3260 mAh, 14.8V |


| Sensor | |
| Scintillator | Direct Deposit CsI:TI |
| Active Area | 434x 434mm |
| Pixel Array | 2816 x 2816 |
| Pixel Pitch | 154 μm |
| Image Quality | |
| Limiting Resolution | 3.25 lp/mm |
| MTF | 70%... … (@ 1 lp/mm) |
| 40% … … (@2 lp/mm) | |
| 22% … … (@3 lp/mm) | |
| DQE | (RQA5,27μGy) |
| ~ 65% … … (@ 0 lp/mm) | |
| ~ 20%… … (@ 3lp/mm) | |
| Sensitivity | ~ 0.62 ct/nGy |
| Response Non-linearity | <± 0.5 % |
| Maximum Linear Dose | >95 μGy |
| Dark Noise | ~ 8 nGy |
| Dynamic Range | ~ 82 dB |
| A/D Conversion | 16 bits |
| Communication | |
| Communication interface | Gigabit Ethernet |
| Image Acquisition Time | 2-3 Sec |
| Exposure control | F²AED |
| Manual Sync | |
| External Sync | |
| Enviornmental | |
| Operating | |
| Temperature Range | 5℃-35℃ |
| Humidity Range (Non-condensing) |
30% - 75% RH |
| Storage | |
| Temperature Range | -20℃-55℃ |
| Humidity Range (Non-condensing) |
10% - 90% RH |
| Mechanical | |
| Dimensions | 460 x 460 x 15 mm |
| Weight | 3.4 kg |
| Housing Material | Carbon Fiber (Front) |
| High Strength Aluminum Alloy(Back) | |
| Power | |
| Maximum Power (standby / operating) |
< 8W / 20W |
| Power Supply | 100-250V AC |
| Frequency | 50 / 60 Hz |
| Regulatory | |
| FDA | K153492 |
| CE | HD601077350001 |
| UL | E464810 |


| Sensor | |
| Scintillator | Direct Deposit CsI:TI |
| Active Area | 430 x 430mm |
| Pixel Array | 3072 x 3072 |
| Pixel Pitch | 140 μm |
| Image Quality | |
| Spatial Resolution | 3.57 lp/mm |
| MTF | 70%... … (@ 1 lp/mm) |
| 40% … … (@2 lp/mm) | |
| 22% … … (@3 lp/mm) | |
| DQE | 60% … … (@ 0 lp/mm) |
| 15% … … (@ 3 lp/mm) | |
| 9% … … (@ 3.5 lp/mm) | |
| A/D Conversion | 16 bits |
| Communication | |
| Image Acquisition Time | 2-3 sec |
| Mechanical | |
| Dimension | 460 x 460 x 15 mm |
| Weight | 3.96 kg |
| Power | |
| Maximum Power (standby/operating) |
< 8W / 20W |
| Power Supply | 100-250V AC |
| Frequency | 50 / 60 Hz |


| Sensor | |
| Scintillator | Direct Deposit CsI |
| Active Area | 430 x 356 mm |
| Pixel Array | 3072 x 2560 |
| Pixel Pitch | 140 μm |
| Image Quality | |
| Spatial Resolution | 3.57 lp/mm |
| MTF | 63% (@ 1.0 lp/mm) |
| 35% (@ 2.0 lp/mm) | |
| 17% (@ 3.0 lp/mm) | |
| DQE | (@ RQA5, 27μGy) |
| 62% (@ 0.0 lp/mm) | |
| 50% (@ 0.5 lp/mm) | |
| 45% (@ 1.0 lp/mm) | |
| A/D Conversion | 16 bits |
| Communication | |
| Communication Interface | Gigabit Ethernet, WiFi (2.4G/5GHz) |
| Image Acquisition Time | 2-4 sec |
| Exposure control | F²AED, Manual Sync, Software Sync |
| AP | Optinal |
| Mechanical | |
| Dimension | 460 x 384 x 15 mm |
| Weight | 3.7 kg |
| Power | |
| Maximum Power (standby/operating) |
Max. 36VA |
| Power Supply | 100-240V AC |
| Frequency | 50 / 60 Hz |
| Battery Performance | Up to 1,400 shots and 5 hours in ready mode |


| Sensor | |
| Scintillator | Direct Deposit CsI |
| Active Area | 430 x 430 mm |
| Pixel Array | 3072 x 3072 |
| Pixel Pitch | 140 μm |
| Image Quality | |
| Spatial Resolution | 3.57 lp/mm |
| MTF | 63% (@ 1.0 lp/mm) |
| 35% (@ 2.0 lp/mm) | |
| 17% (@ 3.0 lp/mm) | |
| DQE | (@ RQA5, 27μGy) |
| 62% (@ 0.0 lp/mm) | |
| 50% (@ 0.5 lp/mm) | |
| 45% (@ 1.0 lp/mm) | |
| A/D Conversion | 16 bits |
| Communication | |
| Communication Interface | Gigabit Ethernet, WiFi (2.4G/5GHz) |
| Image Acquisition Time | 2-4 sec |
| Exposure control | F²AED, Manual Sync, Software Sync |
| AP | Optinal |
| Mechanical | |
| Dimension | 460 x 460 x 15 mm |
| Weight | 4.6 kg |
| Power | |
| Maximum Power (standby/operating) |
Max. 48VA |
| Power Supply | 100-240V AC |
| Frequency | 50 / 60 Hz |
| Battery Performance | Up to 1,400 shots and 5 hours in ready mode |