Features
- SAFE DEFAULT OUTPUT INTENSITY
- SINGLE-USE ELECTRODE FOR HYGIENIC CONCERN
- DUAL CHANNELS WITH FLEXIBLE CONTROL SETTINGS
- PALM-FITTING SIZE DEVICE
- COMBINATION WITH OTHER APPLICATIONS
- WIDE RANGE OF TREATMENT OPTIONS
Features
SAFE DEFAULT OUTPUT INTENSITY
![SAFE DEFAULT OUTPUT INTENSITY](https://www.itocoltd.com/images/products/d-function/images_01.jpg)
The default intensity setting restricts high electrical current output to safely treat the sensitive head and neck regions.
SINGLE-USE ELECTRODE FOR HYGIENIC CONCERN
![SINGLE-USE ELECTRODE FOR HYGIENIC CONCERN](https://www.itocoltd.com/images/products/d-function/images_02.jpg)
Specifically developed highly hygienic disposable electrode (D function pads) are adopted.
DUAL CHANNELS WITH FLEXIBLE CONTROL SETTINGS
The device has 2 independent channels and each channel can flexibly be controlled and set to effectively treat TMJ simultaneously even when they present different conditions.
TMJ and Masseter muscles
![left side](https://www.itocoltd.com/images/products/d-function/images_03-01.jpg)
![the frontY](https://www.itocoltd.com/images/products/d-function/images_03-02.jpg)
![right side](https://www.itocoltd.com/images/products/d-function/images_03-03.jpg)
TMJ and Cervical spine
![left side](https://www.itocoltd.com/images/products/d-function/images_03-04.jpg)
![the back](https://www.itocoltd.com/images/products/d-function/images_03-05.jpg)
![right side](https://www.itocoltd.com/images/products/d-function/images_03-06.jpg)
PALM-FITTING SIZE DEVICE
![PALM-FITTING SIZE DEVICE](https://www.itocoltd.com/images/products/d-function/images_04-01.jpg)
The handy size ensures no restriction in usage environment. The easy-to-use touch display can be operated with surgical gloves.
COMBINATION WITH OTHER APPLICATIONS
![COMBINATION WITH OTHER APPLICATIONS](https://www.itocoltd.com/images/products/d-function/images_05-01.jpg)
D function can effectively be used for pre-treatment in balancing oral muscles. It is also useful as co-treatment with conventional TMJ disorder interventions such as splint therapy.
WIDE RANGE OF TREATMENT OPTIONS
The adopted functional electric waveforms and programs match the multiple needs for TMJ treatment.
-
PAIN mode
For muscle re-education and blood flow increase.
-
(Sweep)
-
(Surge)
-
(Burst)
-
-
CARE mode
Pain relief and muscle relaxation for TMJ.
(Constant)
-
MCR mode
For sensitive skin.
(Constant)
Specifications
Power supply | DC 7.4 V (battery) / DC 12 V (AC Adaptor) |
---|---|
Power consumption | 30 VA |
Number of channels | 2 |
Display | Full-color, 3.5″ LCD touch screen |
Maximum amplitude (peak) | 80 mA |
Frequency | CARE: 0.67 Hz(fixed), PAIN: 200 Hz (max.), MCR: 400 Hz (max.) |
Timer | Max. 60 min. (Max. 480 min. in MCR mode) |
Safety class according to IEC 60601-1 | Class II / Internally powered equipment, Type BF |
Dimensions | 84 (W) x 23.5 (D) x 151 (H) mm |
Weight | 230 g (including a battery) |
Treatment mode | CARE, PAIN, MCR |
Output mode | Surge, Sweep, Burst, Constant |